RAO Technical Logs


Contents


Introduction #

These logs detail the steps of the search-tree algorithm. Activate them if you know the tool pretty well, and in case you want to follow the algorithm in detail.
Most logs contain normal information, but some may contain errors or warnings (possible cases are listed below).

Package name:

com.farao_community.farao.commons.logs.TechnicalLogs

Possible error cases #

Module Name Label Description Consequence
ra-optimisation OR-Tools load error “Native library jniortools could not be loaded. You can ignore this message if it is not needed.” FARAO could not load native library OR-Tools FARAO cannot call a solver to optimize the MIP (range actions). The RAO will only be able to optimize network actions.
commons Randomize string error “There should at least be one try to generate randomized string.”
or
“Failed to create a randomized string with prefix ‘{}’ in {} {}.”
FARAO failed to generate a random string Depends on the calling method (a FaraoException is thrown)
sensitivity-analysis Sensitivity unit error “The Sensitivity Provider should contain at least Megawatt or Ampere unit” The sensitivity is neither in MW nor in A Depends on the calling method (a SensitivityAnalysisException is thrown)

Possible warnings #

Module Name Label Description Consequence
ra-optimisaition Sensitivity computation failure “Systematic sensitivity computation failed on {fallback / default} mode: {error message}” Self-explanatory Depends on the calling method (the SensitivityAnalysisException is re-thrown)
sensitivity-analysis Sensitivity unit error “Unit {unit} cannot be handled by the sensitivity provider as it is not a flow unit” Happens if sensitivity is asked for in an unit other than MW or A Unpredictable
ra-optimisation Leaf error “A computation thread was interrupted” In search tree, if a computation thread on a leaf has been interrupted for a reason. The RAO skips the leaf in error.
ra-optimisation Solver interruption “The solver was interrupted. A feasible solution has been produced.” The solver has been interrupted while optimizing the MIP (for example if max time has been reached), but had time to find a feasible solution. The best feasible solution found by the solver is used.
ra-optimisation Missing GLSK “No GLSK found for CountryEICode {country EIC}” The GLSK is missing for a given country The PTDF is considered equal to zero
sensitivity-analysis PTDF ampere error “PtdfSensitivity provider currently only handle Megawatt unit” This happens when PTDF sensitivity factors are asked for in a unit other than megawatts The warning is printed and the factors are computed in MW